Crestron Control Information

Macro Controls

See below for a sample screen.

SIMPLWINDOWS NAME: Vortex Macros

MANUFACTURER: Polycom
MODEL: Vortex (EF2280)

CATEGORY: MIXER

VERSION: 1.0

SUMMARY: Allows control of all 256 available macros

GENERAL NOTES: The commands used for the Polycom Vortex may be similar to commands used for other Polycom Installed Voice products. Therefore, the same modules developed for the Vortex may work on other products. To allow for this flexibility of use, you must specify which model is being controlled using the TYPE-ID-HEX parameter field. This must be a 2 digit hex representation of the model type as defined by Polycom. For the Vortex, the model type is F, therefore the parameter value to use is 46 which is the hex representation of the letter F. This can be seen by checking any standard ASCII chart. There should be no suffix used after the 46.

Multiple devices can be connected to the ASPI bus and controlled from a single RS232 port. Therefore, it is also necessary to enter the Unit ID of the device being controlled. This should be entered in the UNIT-ID-ASCII parameter field as a two digit number from 00-07 with no suffix.

This module allows macros which have been previously programmed into the system to be troggered by the Crestron system. Note that macros can be set up to allow multiple channels of volume to be controlled simultaneously. See the demo program for an example of how to do this.

CRESTRON HARDWARE REQUIRED: CNXCOM, ST-COM

SETUP OF CRESTRON HARDWARE:
Baud Rate - 9600
Parity - None
Data Bits - 8
Stop Bits - 1
RTS/CTS Handshaking should be enabled to insure no data is lost.

VENDOR FIRMWARE: 1.15

VENDOR SETUP: Ack mode must be set to "on"

CABLE NUMBER: CNSP-141

INPUT DESCRIPTIONS:

Name Type Description
MACRO-0-255 D Pulse to execute a macro
TYPE-ID-ASCII P Enter 46 for Vortex
UNIT-ID-ASCII P Enter the unit number of the Vortex. Should be a number from 00-07

OUTPUT DESCRIPTIONS:

Name Type Description
ASPI-TX$ S Serial signal to be routed to a 2-way RS232 port

OPS USED FOR TESTING: 5.12.26x

COMPILER USED FOR TESTING: SimplWindows Ver 1.61.12

SAMPLE PROGRAM: Vortex Demo Program

REVISION HISTORY: None


Preset Controls

SIMPLWINDOWS NAME: Vortex Presets

MANUFACTURER: Polycom
MODEL: Vortex (EF2280)

CATEGORY: MIXER

VERSION: 1.0

SUMMARY: Allows control of all 48 available presets

GENERAL NOTES: The commands used for the Polycom Vortex may be similar to commands used for other Polycom Installed Voice products. Therefore, the same modules developed for the Vortex may work on other products. To allow for this flexibility of use, you must specify which model is being controlled using the TYPE-ID-HEX parameter field. This must be a 2 digit hex representation of the model type as defined by Polycom. For the Vortex, the model type is F, therefore the parameter value to use is 46 which is the hex representation of the letter F. This can be seen by checking any standard ASCII chart. There should be no suffix used after the 46.

Multiple devices can be connected to the ASPI bus and controlled from a single RS232 port. Therefore, it is also necessary to enter the Unit ID of the device being controlled. This should be entered in the UNIT-ID-ASCII parameter field as a two digit number from 00-07 with no suffix.

This module allows any of the 48 available presets to be recalled. It also allows any of the user definable presets to be saved (Presets 16-47). If you attempt to save any of presets 0-15, it will not work.

Saving a preset is a three step process:
1. Set all the parameters to the desired levels
2. Pulse the PRESET-SAVE input, PRESET-SAVE-FB will go high
3. Pulse the preset number to save the settings into.

To recall a preset, just pulse the preset number.

CRESTRON HARDWARE REQUIRED: CNXCOM, ST-COM

SETUP OF CRESTRON HARDWARE:
Baud Rate - 9600
Parity - None
Data Bits - 8
Stop Bits - 1
RTS/CTS Handshaking should be enabled to insure no data is lost.

VENDOR FIRMWARE: 1.15

VENDOR SETUP: Ack mode must be set to "on"

CABLE NUMBER: CNSP-141

INPUT DESCRIPTIONS:
Name Type / Description
PRESET-0-47 D Pulse to recall a preset. If save mode is active, the preset will be stored
PRESET-SAVE D Pulse to activate/deactivate save mode
TYPE-ID-ASCII P Enter 46 for Vortex
UNIT-ID-ASCII P Enter the unit number of the Vortex. Should be a number from 00-07

OUTPUT DESCRIPTIONS:

Name Type / Description
ASPI-TX$ S Serial signal to be routed to a 2-way RS232 port

OPS USED FOR TESTING: 5.12.26x

COMPILER USED FOR TESTING: SimplWindows Ver 1.61.12

SAMPLE PROGRAM: Vortex Demo Program

REVISION HISTORY: None


Gating Controls and Camera Gating

Logic Inputs and Outputs

Line Level Input Controls

Mic Input Controls

Output Controls

Crestron Website


Back to Main Page | Contact Us