Crestron Control InformationGating ControlsSee below for a sample screen.
SIMPLWINDOWS NAME: ASPI Vortex Gating
MANUFACTURER: Polycom
CATEGORY: MIXER
VERSION: 1.0
SUMMARY: Allows monitoring of gating status
GENERAL NOTES: The commands used for the Vortex may be similar
to commands used for other EF products. Therefore, the same modules
developed for the Vortex may work on other EF products. To allow for
this flexibility of use, you must specify which model is being
controlled using the TYPE-ID-HEX parameter field. This must be a 2 digit
hex representation of the model type as defined by Polycom. For the Vortex,
the model type is F, therefore the parameter value to use is 46 which
is the hex representation of the letter F. This can be seen by
checking any standard ASCII chart. There should be no suffix used after
the 46.
Multiple devices can be connected to the ASPI bus and controlled from
a single RS232 port. Therefore, it is also necessary to enter the Unit ID
of the device being controlled. This should be entered in the
UNIT-ID-ASCII parameter field as a two digit number from 00-07 with no suffix.
This module allows the automatic reporting of gating status to be
enabled/disabled. If the automatic gating status is disabled, you can use
the POLL input to manually poll the gating status. This module will reflect
the gating status at the MIC-*-ON outputs.
CRESTRON HARDWARE REQUIRED: CNXCOM, ST-COM
SETUP OF CRESTRON HARDWARE:
VENDOR FIRMWARE: 1.15
VENDOR SETUP: Ack mode must be set to "on"
CABLE NUMBER: CNSP-141
INPUT DESCRIPTIONS:
OUTPUT DESCRIPTIONS:
OPS USED FOR TESTING: 5.12.26x
COMPILER USED FOR TESTING: SimplWindows Ver 1.61.12
SAMPLE PROGRAM: Vortex Demo Program
REVISION HISTORY: None
SIMPLWINDOWS NAME: Vortex Camera Gating
MANUFACTURER: ASPI
CATEGORY: MIXER
VERSION: 1.0
SUMMARY: Allows monitoring of camera gating status
GENERAL NOTES: The commands used for the Polycom Vortex may be similar
to commands used for other EF products. Therefore, the same modules
developed for the Vortex may work on other EF products. To allow for
this flexibility of use, you must specify which model is being
controlled using the TYPE-ID-HEX parameter field. This must be a 2 digit
hex representation of the model type as defined by Polycom. For the Vortex,
the model type is F, therefore the parameter value to use is 46 which
is the hex representation of the letter F. This can be seen by
checking any standard ASCII chart. There should be no suffix used after
the 46.
Multiple devices can be connected to the ASPI bus and controlled from
a single RS232 port. Therefore, it is also necessary to enter the Unit ID
of the device being controlled. This should be entered in the
UNIT-ID-ASCII parameter field as a two digit number from 00-07 with no suffix.
This module allows the automatic reporting of camera gating status to be
enabled/disabled. If the automatic gating status is disabled, you can use
the POLL input to manually poll the gating status. This module will reflect
the gating status at the MIC-*-ON outputs.
CRESTRON HARDWARE REQUIRED: CNXCOM, ST-COM
SETUP OF CRESTRON HARDWARE:
VENDOR FIRMWARE: 1.15
VENDOR SETUP: Ack mode must be set to "on"
CABLE NUMBER: CNSP-141
INPUT DESCRIPTIONS:
OUTPUT DESCRIPTIONS:
OPS USED FOR TESTING: 5.12.26x
COMPILER USED FOR TESTING: SimplWindows Ver 1.61.12
SAMPLE PROGRAM: Vortex Demo Program
REVISION HISTORY: None